home *** CD-ROM | disk | FTP | other *** search
/ Fritz: All Fritz / All Fritz.zip / All Fritz / FILES / COMMADIO / VT100102.LZH / PC-VT101.ZIP / READ.ME < prev    next >
Text File  |  1991-01-23  |  8KB  |  214 lines

  1.               _______
  2.          ____|__     |               (tm)
  3.       --|       |    |-------------------
  4.         |   ____|__  |  Association of
  5.         |  |       |_|  Shareware
  6.         |__|   o   |    Professionals
  7.       -----|   |   |---------------------
  8.            |___|___|    MEMBER
  9.  
  10.     PC-VT version 10.1    USER Supported Software
  11.  
  12.                     23 January 1991
  13.                     9888 Carroll Center Road Suite 113
  14.                     San Diego, CA 92126
  15.  
  16. Dear User of PC-VT;
  17.  
  18.     Enclosed is the latest version of PC-VT and its documentation.
  19. PC-VT runs on the PC, the PCXT, and the PCAT under DOS 2.x and 3.x.
  20. PC-VT no longer supports DOS 1.x. According to my users, it runs on many
  21. compatibles but I have not tested it on anything except a COMPAQ Deskpro
  22. 286. 
  23.  
  24.     The documentation file is named PC-VT.DOC and can be copied to
  25. any line printer. It's about 190 pages.
  26.  
  27.     This version of PC-VT is the complete Professional version which
  28. has been available for about 3 years. I have taken all of the
  29. enhancements (and bug fixes) of that version and moved them into the
  30. User Supported version of PC-VT. The Professional Version is no longer
  31. sold commercially.
  32.  
  33.     Now more about the version 10.1 of PC-VT. It includes an
  34. enhanced version of the VT-100 emulator and a Tektronix 4010/4014
  35. emulator. It supports both 132 column mode and high resolution graphics
  36. with the addition of the Everex Edge board and high resolution graphics
  37. with the addition of the Hercules graphics board. It supports the VMS
  38. EVE editor as well as EDT and VI with special Keypad key bindings.
  39. Windows are used for file transfer and the program can be completely
  40. controlled by the host for automatic file transfer. The keyboard can be
  41. remapped to suit your taste, screen colors can be set with Escape
  42. Sequences, and you can recall screen data which has scrolled off the top
  43. of the screen.
  44.  
  45.     I have versions of XMODEM for the VAX running VMS ,for UNIX
  46. System V and for UNIX 4.2BSD and a version of ZMODEM which runs under
  47. Unix. You can get those by sending me a formatted 360Kb diskette for
  48. each one you need and a pre-paid pre-addressed diskette mailer. Make
  49. sure you tell me which ones you want. The XMODEM and ZMODEM programs are
  50. public domain.
  51.  
  52.     If you could upload PC-VT to your local BBS, I would appreciate
  53. your help. You can upload this READ.ME file, PC-VT.EXE, HELP.DAT, and
  54. PC-VT.DOC. If you receive this in a .ZIP file, just upload the entire
  55. .ZIP file. If you can put them into a .ZIP file please do and name it
  56. PC-VT101.ZIP.
  57.  
  58.     Both the EXE module and source for PC-VT are available for
  59. commercial distribution. Contact me for details of the licensing
  60. arrangements and fees.
  61.  
  62.     Some of the enhancements for version 10.0 of PC-VT are:
  63.  
  64. 1. The dialer has been enlarged to 100 entries.
  65. 2. ZMODEM and YMODEM are now supported using the external DSZ program from
  66.     Omen Technology, Inc.
  67. 3. PC-VT Supports COM3 and COM4 for serial communications
  68. 4. The printer escape sequences are handled more like a VT terminal.
  69. 5. PC-VT does a better job of emulating the escape sequences to the local
  70.     printer.
  71. 6. PC-VT handles LPT1 through LPT4 and COM1 through COM4 for the
  72.     printer port.
  73. 7. RTS/CTS flow control has been added.
  74. 8. Added a SETUP feature to disable PC-VT Private Sequences.
  75.  
  76.     Some of the enhancements for version 10.1 of PC-VT are:
  77.  
  78. 1. Supports COM1 through COM4 with user selectable interrupt
  79.     vectors and port addresses
  80. 2. Support for some non-ANSI ANSI.SYS escape sequences
  81. 3. Bug in Index and Reverse Index sequences.
  82. 4. Bug fix which prevented macro keys from being set correctly.
  83.  
  84.     Details of the changes are at the end of this read.me and in the
  85. file readme.101
  86.  
  87.     Since this program is user supported, it is user driven. I
  88. continually make upgrades based on user requests.  I bump the version
  89. number only when a significant change occurs. Otherwise, I use a small
  90. letter after the numeric revision number. Here is the list of upgrades
  91. within this version:
  92.  
  93. DATE     #    Function:        Change:
  94. ----    ---    ---------        -------
  95. 01/01/90    First release of version 10.0
  96. 01/23/91    First release of version 10.1
  97.  
  98. Known Bugs in the User Supported Version of PC-VT :
  99.  
  100. None(yet!).
  101.  
  102.     You can always get the latest version of PC-VT from me. Call my
  103. phone number below to find out what the latest version number is. I also
  104. keep the latest version on several San Diego Bulletin Boards. The best
  105. bet is the ATHENA SYSTEMS DEVELOPMENT GROUP's board at 619-549-3927.
  106.  
  107.     I also distribute a program which re-routes printer output to a
  108. disk file. It is called LPTx and 5 unique versions are available. Send a
  109. formatted 360K diskette and a self-addressed diskette mailer if you
  110. would like a copy. Seems to be most useful to users of dBaseIII+. You
  111. can also check for the program on the Athena Systems board mentioned
  112. above. The latest version is 7.0.
  113.  
  114.     I hope that this program is of use to you. If it is and you
  115. register it by sending a $35 copyright fee, I will tell you how to run
  116. the program to get rid of the annoying "send money" message. For an
  117. additional $20, you can order the complete PC-VT printed manual.
  118.  
  119. I would appreciate any comments which you might have regarding the
  120. program or its usefulness. When you write, please indicate the version
  121. number of PC-VT which you are using.
  122.  
  123. Ciao,
  124.  
  125. Mark C. DiVecchio
  126. Athena Systems Development Group
  127. 9888 Carroll Center Road Suite 113
  128. San Diego, CA 92126
  129. 619-549-4056 (office)
  130. RBBS 619-549-3927
  131.  
  132.  
  133. ----------------------------------------------------
  134. Details of changes for version 10.1
  135.  
  136. Athena Systems Development Group
  137. 619-549-4056
  138.  
  139. PC-VT Release 10.1        1/23/91
  140.  
  141. PC-VT now supports a varied combination of communication ports and
  142. interrupt chaining.
  143.  
  144. Using the standard selection mechanism (i.e the 6 key in the SETUP-B
  145. frame after pointing to the correct feature column or the c key), you
  146. can select these combinations :
  147.  
  148. COM    Port    Interrupt
  149.  
  150. 1    3F8    4        Standard
  151. 2    2F8    3        Standard
  152. 3    3E8    4        Pseudo Standard
  153. 4    2E8    3        Pseudo Standard
  154.  
  155. 5    2E8    4        Non Standard
  156. 6    2E0    3        Non Standard
  157.  
  158.  
  159. COM 1 and 2 are the standard ports. COM 3 and 4 are the almost standard
  160. ports. COM 5 and 6 are used on some boards as what they call COM 3 and 4.
  161.  
  162. For additional flexibility, you can select one of these ports and change
  163. the Interrupt IRQ number. To change the IRQ number, select the correct
  164. port with the 'c' key and then press the 'i' key. Each time you press
  165. the 'i' key, the IRQ number will go up by one. It will cycle 0-7 and
  166. repeat. Pick the IRQ number you want. Make sure you select a 'good' IRQ
  167. number for your system. Selecting a 'bad' IRQ number (like one the disk
  168. drive uses) will surely lock up your computer.
  169.  
  170. The port and IRQ information is saved with the SETUP and DIALER just
  171. like all the other feature selections.
  172.  
  173. PC-VT also supports interrupt chaining. If you have two ports on a
  174. single IRQ line, PC-VT checks the port's IID register. If the Interrupt
  175. Pending bit is not on, it chains any other ISR that may be attached to
  176. that IRQ line.
  177.  
  178. Thanks to Malcolm Michael at Triad for prompting this enhancement.
  179.  
  180.  
  181. Other New Features and Bug Fixes :
  182. ----------------------------------
  183.  
  184. 1. On the ANSI/VT52 selection on the SETUP B screen, you can now select
  185.  
  186.     VT52
  187.     ANSI
  188.     ANSI.SYS
  189.  
  190.     from the following prompt:
  191.  
  192.     ANSI/VT52        0=VT52  1=ANSI (VT100/102)  2=ANSI.SYS
  193.  
  194.     The new selection ANSI.SYS makes PC-VT interpret escape sequences
  195.     more like ANSI.SYS and less like the ANSI standard. Microsoft
  196.     chose to change some of the sequences when they developed 
  197.     ANSI.SYS.
  198.  
  199.     Enables these sequences :
  200.  
  201.         <ESC>[2m    clear the screen and home the cursor
  202.  
  203.     Enables these characters :
  204.  
  205.         <FF>        clear the screen and home the cursor
  206.  
  207. 2. Fixed a bug in the Index and Reverse Index sequences. They should
  208.     only scroll the window if the cursor is ON the top/bottom
  209.     line of the margin. Found by George Fluck at Standard and Poors.
  210.  
  211.  
  212. 3. Fixed a bug in loading of Table keys if macro keys were not done
  213.      first. Found by George Fluck at Standard and Poors.
  214.